The “7000-10-7F22” error occurs when the ECU returns a condition not satisfied (NRC 0x22) response to an open communication request. The main causes are IG status mismatch (engine ON state), incorrect upgrade mode selection, or interference from aftermarket devices. This can be resolved by adjusting the vehicle IG status, rechecking the upgrade mode, or removing aftermarket devices.
Symptoms
The “7000-10-7F22” error occurs immediately after starting the upgrade or in the early stages, and the process does not begin.
Causes
- The vehicle is in engine ON state, so communication conditions are not met (IG ON required)
- Upgrade mode (automatic/manual) selection error
- Communication initialization is disrupted by aftermarket devices
- Unstable voltage prevents the ECU from maintaining communication-ready status
Solutions
Step 1) Adjust IG Status
Switch the vehicle from engine OFF to IG ON status.
(Most ECUs do not allow open communication in engine ON state)
Step 2) Recheck Upgrade Mode
Check that the correct ECU/category is selected in automatic or manual mode.
Step 3) Remove Aftermarket Devices
Remove all devices that may interfere with communication, such as dash cams, communication modules, or taxi equipment, then try again.
Step 4) Stabilize Vehicle Voltage
If the battery voltage is low, connect an external power maintainer.
Step 5) Vehicle Power Reset
Caution: Some vehicle settings may be reset when disconnecting the battery (-) terminal.
1) Turn off the vehicle power completely.
2) Disconnect the battery (-) terminal for more than 5 minutes.
3) Reconnect and try the upgrade again.