| Post Type | ☐ Information ☐ Repair ☑ Instructions | Applicable Region |
| Applicable Equipment |
☑ KDS 2.0/Mobile ☑ GNESIS Smart/Mobile ☑ KDS 2.0/KDS 1.0 ☑ ULT-100 |
All Regions |
| Publication Date | (KST) 21-Jan-2025 | Publication Period |
| Subject | [Battery Pack Airtightness Test] Conditions That May Trigger the "Air Vent Check" Message | ☐ Temporary ☑ Permanent |
Symptom:
The "Air Vent Check" message may appear in the diagnostic application under the following conditions:
-
The pressure equalization element is missing from the air injection adapter mounting area on the EV battery pack upper case.
- Corrective action: Properly install the pressure equalization element.
-
The silicone O-ring is missing from the bottom surface of the air injection adapter.
- Corrective action: Install the silicone O-ring in the correct position and remove any foreign material from the sealing surface.
-
The pack inlet (pressure equalization element) installed on the battery upper case is improperly assembled and does not seat correctly against the bottom sealing surface.
- Cause: The pressure equalization element may be clogged with foreign material or improperly assembled.
-
Corrective action: Remove any foreign material from the pack inlet (pressure equalization element) mounting area and replace the component with a new one if necessary.